KNX – TWISTED PAIR (KNX-TP)

SENSORS

  • TOUCH TEMPERATURE CONTROLLER WITH FAN SPEED KEY – TM KNT 001

    • KNX Capacitive Touch Thermostat for room temperature control with button to adjust the Fan Speed.
    • It incorporates a Display that shows both the Setpoint or Ambient Temperature and the Relative Humidity of the environment.
    • 4 buttons with preset functionality:

    – Decrease Set-point Temperature
    – Increase Set-point Temperature
    – Switch On/Off Thermostat
    – Fan-Coil Speed

    • In addition, there are 2 free buttons which can be configured as a Switch, Dimmer, Control of Blinds / Shutters, Scenes, etc.
    • Integrated Temperature Sensor, Brightness Sensor and Relative Humidity.
    • Fancoil Speed LED.
    • Its main functionality is complemented with 4 Binary / Analog Inputs, which can be connected to a Door / Window Contact or a DINUY Temperature Probe.
    • Allows enabling and configuring one Heating and / or Cooling Thermostat.
    • Press or status indicator LEDs with ETS configurable luminosity and RGB color on the 2 freely configurable keys.
    • No need external power, only the KNX Bus.
    • KNX Bus Coupling Unit (BCU) integrated.
    • Designed for flush mounting into universal mechanism box.
    • Commissioning by ETS5 or later versions.

  • TOUCH TEMPERATURE CONTROLLER WITH HVAC MODE KEY – TM KNT 002

    • KNX Capacitive Touch Thermostat for room temperature control with button to adjust the HVAC operating mode.
    • It incorporates a Display that shows both the Setpoint or Ambient Temperature and the Relative Humidity of the environment.
    • 4 buttons with preset functionality:

    – Decrease Set-point Temperature.
    – Increase Set-point Temperature.
    – Switch On/Off Thermostat.
    -HVAC Mode.

    • In addition, there are 2 free buttons which can be configured as a Switch, Dimmer, Control of Blinds / Shutters, Scenes, etc.
    • Integrated Temperature Sensor, Brightness Sensor and Relative Humidity.
    • HVAC mode LED.
    • Its main functionality is complemented with 4 Binary / Analog Inputs, which can be connected to a Door / Window Contact or a DINUY Temperature Probe.
    • Allows enabling and configuring one Heating and / or Cooling Thermostat.
    • Press or status indicator LEDs with ETS configurable luminosity and RGB color on the 2 freely configurable keys.
    • No need external power, only the KNX Bus.
    • Designed for flush mounting into universal mechanism box.
    • Commissioning by ETS5 or later versions.

  • 4-CHANNEL BINARY INPUT/OUTPUT – EM KNT 001

    • Interface with 4 independent channels, which can work as Binary Input or LED Output.
    • Equipped with 4 Digital (Binary) inputs which may be conmnected to a conventional push-button, switch or binary sensor with free-voltage contact.
    • Each of the 4 channels has the following configurable functions with the ETS:
      • Switch: to turn the light ON and OFF.
      • Switch and Dimmer: to turn ON/OFF and dim the light.
      • Multiple Switch: to turn ON/OFF the light depending on the number of press.
      • Sequential Switch: to do sequential switching ON/OFF.
      • Blinds/Shutters Control: to move the blinds/shutter by push buttons or switches.
      • Scenes Control: to save and recover a light scene.
      • Values Sending: to send different measures or values, for example the light level, temperature,….
      • Impulse Counter: it allows, for example, counting the number of operations.
      • LED visualization.
    • Universal- or Junction-box mounting.
    • Programming and commissioning via ETS4 or later versions.
  • 4-CHANNEL BINARY/ANALOG INPUT – EM KNT 002

    • Interface with 4 independent channels, which can work as Binary or Analog Input.
    • The Digital (Binary) inputs which may be conmnected to a conventional push-button, switch or binary sensor with free-voltage contact.
    • Each of the 4 channels has the following configurable functions with the ETS:

    – Switch: to turn the light ON and OFF.
    – Switch and Dimmer: to turn ON/OFF and dim the light.
    – Multiple Switch: to turn ON/OFF the light depending on the number of press.
    – Sequential Switch: to do sequential switching ON/OFF.
    – Blinds/Shutters Control: to move the blinds/shutter by push buttons or switches.
    – Scenes Control: to save and recover a light scene.
    – Values Sending: to send different measures or values, for example the light level, temperature,….
    – Impulse Counter: it allows, for example, counting the number of operations.
    – Temperature Sensor (ST KNT 001 & ST KNT 002 probes).

    • Up to 4 Heating and / or Cooling Thermostats.
    • Universal- or Junction-box mounting.
    • Programming and commissioning via ETS4 or later version.

  • 8-CHANNEL BINARY INPUT – EM KNT 003

    • Interface with 8 independent channels, which can work as Binary Input.
    • Equipped with 8 Digital (Binary) inputs which may be conmnected to a conventional push-button, switch or binary sensor with free-voltage contact.
    • Connection cables can be extended up to 200m.
    • Each of the 8 channels has the following configurable functions with the ETS:

    – Switch: to turn the light ON and OFF.
    – Switch and Dimmer: to turn ON/OFF and dim the light.
    – Multiple Switch: to turn ON/OFF the light depending on the number of press.
    – Sequential Switch: to do sequential switching ON/OFF.
    – Blinds/Shutters Control: to move the blinds/shutter by push buttons or switches.
    – Scenes Control: to save and recover a light scene.
    – Values Sending: to send different measures or values, for example the light level, temperature,….
    – Impulse Counter: it allows, for example, counting the number of operations.

    • Universal- or Junction-box mounting.
    • Programming and commissioning via ETS5 or later version.

  • CEILING-MOUNTED KNX MOVEMENT DETECTOR – DM KNT 001

    • KNX PIR motion detectors with luminosity sensor.
    • The lux level and time delay can be set with the control knobs, by using the IR remote control (EM MAN DM0) or via ETS.
    • One PIR sensor and a high resolution lens can detect the smallest movement.
    • Depending on the parameterization by ETS, this detectors can work as:

    – Motion detection: depending on the movement and the daylight.
    – Twilight switch: teach-in brightness threshold for daylight-dependent switching.
    – Constant light control: with dimming telegrams.
    – Signal monitoring: motion detection without brightness sensor.
    – Brightness sensor: light sensor without motion detection.
    – Temperature sensor: sends the temperature value.

    • Detection area of 360º and maximum 7m at 2.5m high.
    • Flush ceiling mounted.
    • Power supplied by the Bus.
    • Programation by ETS3 or later version.

  • MECHANISM-BOX-MOUNTED KNX MOVEMENT DETECTOR – DM KNT 003

    • KNX PIR Motion Detector with luminosity sensor.
    • The lux level and time delay can be set with the control knobs, by using the IR remote control (EM MAN DM0) or via ETS.
    • One PIR sensor and a high resolution lens can detect the smallest movement.
    • Depending on the parameterization by ETS, this detectors can work as:

    – Motion detection: depending on the movement and the daylight.
    – Twilight switch: teach-in brightness threshold for daylight-dependent switching.
    – Constant light control: with dimming telegrams.
    – Signal monitoring: motion detection without brightness sensor.
    – Brightness sensor: light sensor without motion detection.
    – Temperature sensor: sends the temperature value.

    • Flush mounted in universal mechanism box.
    • Detection area of 200º and maximum 8m.
    • Programming and commissioning by ETS3 or later version.

  • MOVEMENT DETECTOR FOR KNX INPUTS – DM KNT 004

    • PIR motion detector to be directly connected to input of EM KNT 002, EM K5X 004 or RE KNT LE3.
    • As soon as it detects a movement, and the light level is lower than the threshold value, an ON telegram will be sent to the input of the interface to which it is connected. After the time delay has elapsed, the OFF telegram will be sent. The timing is restarted every time a new movement is detected.
    • Lux level and Time Delay can be set via control knobs.
    • No external supply required.
    • Flush-ceiling mounting.
    • Coverage: 360º & Ø7m at 2,5m high.

  • NTC TEMPERATURE PROBE FOR ANALOGUE INPUTS Ø7mm – ST KNT 001

    • NTC temperature probe for Analogue Inputs.
    • Probe length: 3 meters. 
    • Diameter: 7mm.
  • NTC TEMPERATURE PROBE FOR ANALOGUE INPUTS Ø5mm – ST KNT 002

    • NTC Epoxy Temperature probe por Analogue Inputs.
    • High accuracy and stability over a wide temperature range.
    • A cable os 0.5m length is included. Ø5mm.

ACTUATORS

  • Switching actuator with 4 output channels and dimmer for RGBW LED strips – IR KNT 044

    • Multifunction actuator that can wok as a dimmer for RGBW LED strips with 4 output channels and:
      • Switching of 4 independent output channels
      • Actuator for Blinds/Awnings with 2 output channels
      • 1 Fan-Coil Actuator with 2 pipes (On/Off Valve and 3 Fan Speeds).
    • Installation on DIN rail.
    • Manual forcing of each channel by means of buttons on the front of the actuator, without the need for a Bus connection.
    • Possibility of 12 Binary and/or Analog Inputs: 8 Binary + 4 Binary/Analog.
    • Status LED indicators for each output channel.
    • LED status indicators for error status.
    • It is possible to enable up to 8 different functions: timer, scenes, logic operations, forced operation, etc.
    • Programming and commissioning using ETS5, or later versions.
  • 2-CHANNEL SWITCH/BLIND ACTUATOR – IT KNT 001

    • 2-channel Switching Actuator or 1-channel Blinds / Awnings Actuator.
    • Maximum switching capacity of up to 16A per channel, 2 voltage-free contacts.
    • Modular housing (1 module wide), DIN-rail mounting.
    • Incorporates 2 potentiometers, each of which allows manual control in the form of a test, without the need for the Bus.
    • It is possible to enable different functions: timer, preset, scenes, logic operations, forced operation …
    • Programming and commissioning using ETS3, or later versions.

  • 4-CHANNEL SWITCH/BLIND ACTUATOR WITH 12 INPUTS – IT KNT 004

    • 4-channel Multi-function Switching Actuator or 2-channel Blinds/Shutters Actuator.
    • High load capacity, with 16A built-in relays, as well as a zero-crossing-point control, which allows switching very high loads, even capacitive type.
    • Incorporates 12 Inputs: 8-Binary Inputs + 4-Binary/Analog Inputs.
    • These inputs can be independently parameterized through the ETS Software:

    – Binary Input: allows the connection of a conventional voltage-free binary sensor or switch.
    – Analog Input: allows the connection of a DINUY temperature probe (ST KNT 001 or ST KNT 002).

    • Incorporates a front keypad for independent manual control of each output, as well as status indicator LEDs.
    • Allows to enable and configure up to 4 independent Heating and / or Cooling Thermostats.
    • It incorporates 8 Logic Functions, Centralized Control, Scenes, Time Function, etc.
    • Possibility of connecting different phases in each output channel.
    • DIN-rail mounting, 4 modules wide.
    • Programming and commissioning via ETS5 or later versions.

  • 8-CHANNEL SWITCH/BLIND ACTUATOR WITH 12 INPUTS – IT KNT 008

    • KNX Multifunction Actuators that can work as 8-channel Switching Actuator or 4-channel Blinds/Shutters Actuators.
    • High load capacity, with 16A built-in relays, as well as a zero-crossing-point control, which allows switching very high loads, even capacitive type.
    • Incorporate 12 Inputs: 8-Binary Inputs + 4-Binary/Analog Inputs.
    • These inputs can be independently parameterized through the ETS Software:

    – Binary Input: allows the connection of a conventional voltage-free binary sensor or switch.
    – Analog Input: allows the connection of a DINUY temperature probe (ST KNT 001 or ST KNT 002).

    • Incorporates a front keypad for independent manual control of each output, as well as status indicator LEDs.
    • Allows to enable and configure up to 4 independent Heating and / or Cooling Thermostats.
    • Incorporates 8 Logic Functions, Centralized Control, Scenes, Time Function, etc.
    • Possibility of connecting different phases in each output channel.
    • DIN-rail mounting, 4 modules wide.
    • Programming and commissioning via ETS5 or later versions.

  • 16-CHANNEL SWITCH/BLIND ACTUATOR WITH 23 INPUTS – IT KNT 016

    • KNX Multifunction Actuator that can work as: 16-channel Switching Actuator or 8-channel Blinds/Shutters Actuator.
    • High load capacity, with 16A built-in relays, as well as a zero-crossing-point control, which allows switching very high loads, even capacitive type.
    • Incorporate 23 Inputs: 16-Binary Inputs + 7-Binary/Analog Inputs.
    • These inputs can be independently parameterized through the ETS Software:

    – Binary Input: allows the connection of a conventional voltage-free binary sensor or switch.
    – Analog Input: allows the connection of a DINUY temperature probe (ST KNT 001 or ST KNT 002).

    • Incorporates a front keypad for independent manual control of each output, as well as status indicator LEDs.
    • Allows to enable and configure up to 7 independent Heating and / or Cooling Thermostats.
    • It incorporates 16 Logic Functions, Centralized Control, Scenes, Time Function, etc.
    • Possibility of connecting different phases in each output channel.
    • DIN-rail mounting, 8 modules wide.
    • Programming and commissioning via ETS5 or later versions.

  • 2-CHANNEL SWITCH/BLIND ACTUATOR WITH 4 INPUTS – PE KNT 001

    • KNX Switching Actuator which can work as:

    – 2-channel Switching Actuator.
    – 1-channel Blinds/Shutters Actuator.

    • It has 4 Analog/Digital inputs, which can be configured independently, through the ETS:

    – Digital inputs (binary): allows the connection of a pushbutton, switch or conventional binary sensor, free-voltage contact.
    – Analog inputs: allows the connection of a temperature probe (ST KNT 001 or ST KNT 002).

    • Programming and commissioning via ETS5 or later version.

  • 2-CHANNEL SWITCH/BLIND ACTUATOR WITH 4 INPUTS – PE KNT 002

    • Multifunction actuator with 2 outputs for 1 blind/shutter control or 2 individual outputs.
    • Can work as:

    – 2-channel Switching Actuator.
    – 1-channel Blinds/Shutters Actuator.

    • It has 4 Analog/Digital inputs, which can be configured independently, through the ETS:

    – Digital inputs (binary): allows the connection of a pushbutton, switch or conventional binary sensor, free-voltage contact.
    – Analog inputs: allows the connection of a temperature probe (ST KNT 001 or ST KNT 002).

    • In addition, it allows enabling and configuring up to 4 independent Thermostat.
    • In case it is configured as 1-channel blinds/shutters actuator, the following alarms and functions are available: Wind alarm, Rain alarm, Frost alarm, Sun Protection function, Scene control and Forced function.
    • In case it is configured as 2-channel switch actuator, the following functions are available in each channel: Timer, Preset value, Scene control, Logical functions, Forced and Threshold function.
    • Each of the four inputs has the following functions: Switch, Switch/Dimmer, Multiple Dimmer, Sequential Switch, Blind Control, Scene Control, Fixed/Forced Function, Counter and Temperature Sensor.
    • Maximum load capacity of up to 10A per channel.
    • Programming and commissioning via ETS5 or later version.

  • 1-CHANNEL RLC+LED DIMMING ACTUATOR WITH 4 INPUTS – RE KNT LE3

    • 1-channel Universal Dimming Actuator, in small housing.
    • Phase control dimming technology (leading- or trailing-edge), being valid for different types of load RLC+LED:

    – 230V~ Dimmable LED lamps.
    – 12V~ Dimmable LED lamps with electronic transformer.
    – Incandescence and 230V Halogens.
    – 12V Halogens with electronic transformer.

    • It has 4 Analog/Digital inputs, which can be configured independently, through the ETS:

    – Digital inputs (binary): allows the connection of a pushbutton, switch or conventional binary sensor, free-voltage contact.
    – Analog inputs: allows the connection of a temperature probe (ST KNT 001 or ST KNT 002).
    – Motion Detector: by connecting the sensor DM KNT 004.

    • Each of the four inputs has the following functions: Switch, Switch/Dimmer, Multiple Dimmer, Sequential Switch, Blind Control, Scene Control, Fixed/Forced Function, Counter and Temperature Sensor.
    • In addition, it allows to enable and configure up to 4 independent Thermostats.
    • It admits the connection of an Auxiliary Pushbutton (D) for the control of the Dimming.
    • Actuator or of another different actuator. Its functionality must be parameterized through the ETS.
    • Protected against overloads and short circuits. It incorporates heating protection of resettable operation.
    • Mounting into junction box.
    • Programming and commissioning by ETS5 or later version.

  • 1-CHANNEL RLC+LED DIMMING ACTUATOR – RE KNT 000

    • Universal Dimming Actuator for:

    – Incandescence and 230V Halogen lamps.
    – LV Halogen lamp with ferromagnetic transformer.
    – LV Halogen lamp with electronic transformer.
    – Dimmable 230V LED lamps.
    – Dimmable 12V~ LED lamps (electronic transformer).
    – Dimmable Compact Fluorescent lamps.

    • Leading or Trailing edge dimming technology.
    • 1 channel with a maximum load capacity of 1.000W.
    • Optional manual dimming control by built-in potentiometer (even without bus connection).
    • Protected against overloads and short-circuits. Built-in resettable heating protection.
    • Modular installation device. DIN-rail mounting. 5-modules wide.
    • Anti-panic input for safety systems: disabling this input, the lamps will turn on to the maximum brightness ignoring the dimming.
    • Programming and commissioning by ETS3 or later version.

  • 4-CHANNEL RLC+LED DIMMING ACTUATOR – RE KNT 004

    • 4-channel Universal Dimming Actuator for:
    – Incandescence and 230V Halogen lamps.
    – LV Halogen lamp with electronic transformer.
    – Dimmable 230V LED lamps.
    – Dimmable 12V – LED lamps (electronic transformer).
    • Leading or Trailing edge dimming technology.
    • Optional manual dimming control by built-in potentiometer (even without bus connection).
    • Protected against overloads and short-circuits. Built-in resettable heating protection.
    • Modular installation device. DIN-rail mounting. 5-modules wide.
    • Anti-panic input for safety systems: disabling this input, the lamps will turn on to the maximum brightness ignoring the dimming.
    • Programming and commissioning via ETS4 or later version.

  • 8-CHANNEL RLC+LED DIMMING ACTUATOR – RE KNT 008

    • Dimming Actuator with 8 output channels, designed for the control of resistive, inductive, capacitive and LED loads.
    • Phase-cut dimming technology, both leading and trailing edge, configurable by ETS parameter:

    – 230V dimmable LED Lamps.
    – 12V dimmable LED Lamps with Electronic transformer. o Incandescent and 230V Halogens.
    – Halogens with Electronic transformer.

    • The 8 channels can be configured as:

    – Independent channels: It allows to control the different output channels independently.
    – Sequencer: The 8 channels are controlled together at the same time with predefined sequences.

    • It incorporates a keyboard on its front that allows manual control of each of the channels.
    • Protected against overloads and short circuits. It incorporates heating protection with resettable operation.
    • It has an LED indicating error due to over-temperature or overload.
    • Modular housing (8 modules width), for DIN-rail mounting.
    • Programming and commissioning via ETS5 or later versions.

  • 3-CHANNEL DALI DIMMING ACTUATOR – RE KNT DA1

    • 3-channel Broadcast DALI Dimming Actuator.
    • Each channel can control up to 64 DALI Drivers (128 in total).
    • Unidirectional and Broadcasting communication with the lighting fixtures.
    • Integrated overload, short-circuit and over-heating protection.
    • Anti-panic input for safety systems.
    • DIN-rail mounting, 5 modules wide.
    • Manual operation on device by Potentiometer (even without bus connection).
    • Programming and commissioning by ETS4 or later version.

  • 3-CHANNEL 1-10V DIMMING ACTUATOR – RE KNT 110

    • 1-10V Dimming Actuator for Drivers or Ballasts, with fluorescent tubes or LED lighting.
    • 3 output channels, with a maximum of 3A per channel.
    • It has 2 control elements for switching/dimming the load:

    – K relay: 3 independent contacts that open or close the phase output to the drivers or ballasts. Therefore, with this relay, we will control the power supply of the luminaires. If a greater number of electronic ballasts or drivers with high inrush currents are to be connected, a separate load contactor is recommended.
    – 1-10V Analogue Output: dimming signal. The number of electronic ballasts or drivers that can be dimmed via the 1-10V output, depends on the ballast-specific 1/10V input current of the types used.

    • Different functions and parameters can be enabled and parameterised by the ETS: staircase lighting timer with warning function, dimming speed, scene control (up to 5), sequential operation, soft turn on/off, etc.
    • Outputs can be operated manually (even without bus connection).
    • The device has integrated overload, short-circuit and over-heating protection.
    • Modular installation device. DIN-rail mounting. 5-modules wide.
    • Programming and commissioning by ETS4 or later versiom.

  • 4-CHANNEL LED STRIPS DIMMING ACTUATOR – RE KNT RGB

    • 4-channel LED Strips Dimming Actuator.
    • Allows the control of 4 independent single-color, RGBW or RGB + W LED Strips.
    • Valid for LED Strips with constant voltage input 12V-24V.
    • PWM dimming technology.
    • High load capacity. Incorporates 4 output channels with maximum 10A per channel, and a maximum capacity of 40A in total.
    • Built-in front rotary knob which allows to check, manually, the correct operation of the dimmer, without KNX Bus.
    • Protected against overloads and short-circuits. Incorporates resettable heating protection.
    • Modular housing, DIN-rail mounting (5u).
    • Programming and commissioning via ETS4 or later version.

COMMUNICATION

  • USB/KNX INTERFACE STICK – CO KNT 002

    • KNX USB Interface Stick.
    • Establishes a bidirectional connection between a PC and the KNX installation bus.
    • Galvanic separation from the KNX bus.
    • Both ETS versions ETS3 or later and some visualization tools supports this interface.

POWER SUPPLY

  • 640mA POWER SUPPLY – FA KNT 001

    • 640mA Power Supply which produces and monitors EIB/KNX system voltage.
    • The bus line is decoupled from the power supply with the integrated choke.
    • The power supply is connected to the bus line with a bus connection terminal.
    • A 30VDC auxiliary voltage is made available via an additional connection terminal. This voltage can be used to supply a further bus line (in connection with a separate choke).