KNX – TWISTED PAIR (KNX-TP)

SENSORS

EM KNT 001 - Lámparas y tiras LED - Dinuy
EM KNT 001
  • Universal Interface with 4 binary inputs and 4 LED outputs.
  • The Universal Interface has 4 channels which can be parameterised as inputs or outputs, e.g. for connection of conventional pushbuttons, free-voltage motion detectors, etc.
  • The interface can evaluate at its potential-free inputs up to 4 pushbutton/switch states with      a common reference potential and send the corresponding telegrams.
  • The telegrams may be for switching or dimming, blind/shutter control, value transmitter applications (light level, temperature,…), light scene control or pulse counting. As an alternative, the four channels can control four LEDs as independent outputs.
  • The outputs are protected against short circuits, overload and wrong polarity.
  • This device is flush mounted in a universal box, behind the pushbutton/switch.
EM KNT 002
  • It has 4 independent channels, which can function as binary or analog inputs, depending on how parametricen by ETS software.
  • This device can be used as interface buttons or switches, for reading binary inputs or as analog temperature sensor input (with external probe).
  • Power supplied by the Bus.
  • Each of the four channels has the following functions: switching, dimming, blinds control, Scene Control, Pulse Count, temperature control, thermostat, etc.
ST KNT 001
  • NTC temperature probe for EM KNT 002 sensor.
  • Probe length: 3 meters.

 

ST KNT 002
  • NTC Epoxy Temperature probe.
  • High accuracy and stability over a wide
    temperature range.
  • A cable of 0.5m lenght is included. Ø5mm.

 

DM KNT 001
  • KNX PIR motion detectors with luminosity sensor.The lux level and time delay can be set with the control knobs, by using the IR remote control (EM MAN DM0) or via ETS.
  • One PIR sensor and a high resolution lens can detect the smallest movement.
  • The built-in light sensor measures the brightness on a continuous basis and compares it to the level preset on the control knob (or by means of the remote control EM MAN DM0 or by ETS).
  • Depending on the parameterization by ETS, this detectors can work as:
    · Motion detection: depending on the movement and the daylight.
    · Twilight switch: teach-in brightness threshold for daylight-dependent switching.
    · Constant light control: with dimming telegrams.
    · Signal monitoring: motion detection without brightness sensor.
    · Brightness sensor: light sensor without motion detection.
    · Temperature sensor: sends the temperature value.
  • Detection area of 360º and maximum 7m at 2.5m high.
  • Flush ceiling mounted.
  • Power supplied by the Bus.
  • Programing by ETS: program ETS3 ó  program ETS4
  • Download Instructions.
  • Download User Guide.
DM KNT 002
  • KNX PIR motion detectors with luminosity sensor.The lux level and time delay can be set with the control knobs, by using the IR remote control (EM MAN DM0) or via ETS.
  • One PIR sensor and a high resolution lens can detect the smallest movement.
  • The built-in light sensor measures the brightness on a continuous basis and compares it to the level preset on the control knob (or by means of the remote control EM MAN DM0 or by ETS).
  • Depending on the parameterization by ETS, this detectors can work as:
    · Motion detection: depending on the movement and the daylight.
    · Twilight switch: teach-in brightness threshold for daylight-dependent switching.
    · Constant light control: with dimming telegrams.
    · Signal monitoring: motion detection without brightness sensor.
    · Brightness sensor: light sensor without motion detection.
    · Temperature sensor: sends the temperature value.
  • Wall mounted.
  • Detection area of 180º and maximum 10m at 2m high.
  • Programation by ETS: programa ETS3 / programa ETS4
  • Download Instructions
  • Download User Guide.

 

DM KNT 003
  • KNX PIR motion detectors with luminosity sensor.The lux level and time delay can be set with the control knobs, by using the IR remote control (EM MAN DM0) or via ETS.
  • One PIR sensor and a high resolution lens can detect the smallest movement.
  • The built-in light sensor measures the brightness on a continuous basis and compares it to the level preset on the control knob (or by means of the remote control EM MAN DM0 or by ETS).
  • Depending on the parameterization by ETS, this detectors can work as:
    · Motion detection: depending on the movement and the daylight.
    · Twilight switch: teach-in brightness threshold for daylight-dependent switching.
    · Constant light control: with dimming telegrams.
    · Signal monitoring: motion detection without brightness sensor.
    · Brightness sensor: light sensor without motion detection.
    · Temperature sensor: sends the temperature value.
  • Flush mounted in universal mechanism box.
  • Detection area of 200º and maximum 8m.
  • Programation by ETS: programa ETS3 / programa ETS4
  • Download Instructions
  • Download User Guide.

 

ACTUATORS

IT KNT 001
  • 1-channel blinds actuator or 2-channel switch.
  • Up to 16A switching capacity per channel.
  • Power supplied by the Bus.
  • Possibility of manual operation from the device.
  • Installation in DIN rail.
IT KNT 004
  • 4-channel switching actuator.
  • Maximun load: 16A per channel.
  • Installation in DIN rail.
  • Power supplied by the Bus.
IT KNT 012
  • 12-channel switching actuator.
  • Maximun load: 16A per channel.
  • Installation in DIN rail.
  • Power supplied by the Bus.
RE KNT 000
  • Universal dimmer , 1 channel for RLC and LED loads.
  • Load: incandescent, halogen , LED , Fluorescent – Compact …
  • Up to 1,000 W Incandescent maximum capacity .
  • Installation on DIN rail
  • Power 230V
RE KNT 004
  • 4-channel Dimming Actuator for:
    · Incandescence and 230V Halogen lamps.
    · LV Halogen lamp with electronic transformer.
    · Dimmable 230V LED lamps.
    · Dimmable 12V~ LED lamps (electronic transformer).
  • Leading or Trailing edge dimming technology.
  • Optional manual dimming control by built-in potentiometer (even without bus
    connection).
  • Protected against overloads and short-circuits. Built-in resettable heating
    protection.
  • Modular installation device. DIN-rail mounting.
  • 5-modules wide.
  • Anti-panic input for safety systems: disabling this input, the lamps will turn on to
    the maximum brightness ignoring the dimming.
  • Built-in KNX BCU (Bus Coupler Unit).
RE KNT DA1
  • 3-channels modular DALI dimming actuator (up to 64 equipments per channel).
  • Protected against overloads and short-circuits. Built-in heating protection.
  • Anti-panic input for safety systems.
  • Installation in DIN rail.
  • Power supply 230V.
RE KNT 110
  • 3-channel modular 1-10VDC dimming actuator.
  • Protected against overloads and short-circuits. Built-in heating protection.
  • Anti-panic input for safety systems.
  • Installation in DIN rail.
  • Power supply 230V.
RE KNT RGB
  • Dimming actuator to control RGBW LED strips .
  • Power supply:12Vcc – 24Vcc.
  • It has 4 output channels 10A per channel , with a maximum capacity of 40A.
  • Control via KNX PT ( Twisted Pair to 24VDC ).
  • Protected against overloads and short-circuits.
  • Modular installation device, DIN-rail mounting. 5-modules wide.
  • Anti-panic input for safety systems.

 

COMMUNICATION

CO KNX 002
  • The Media Coupler connects wireless KNX devices (KNX-RF Easy-mode) with the KNX Bus
    (KNX-TP).
  • Therefore wired actuators can be controlled by wireless sensors as well as wireless actuators can be controlled by wired transmitters (bidirectional communication).
  • Can be used together with devices to control lighting, HVAC, blinds/shutters and main purpose
    devices.
  • Up to 16 channels which can be parameterised with one of the following functions:
    · Light channel.
    · HVAC channel.
    · Common channel.
    · Shutter/Blind channel.
  • Is able to forward the battery status of connected wireless devices to the KNX Bus.
  • In addition, the coupler can act as RF retransmitter.
  • Dimensions: 78 x 28 x 23mm.
  • Power supply: BUS KNX 24VDC.

 

CO KNT 001
  • Communication interface between DINUY dimmers and any KNX-TP compatible divice.
  • Al the moment that receives a signal from a sensor transmits the order to the dimmer, being possible to control almost any type of load.
  • Compatible with all DINUY modular dimmers. Unidirectional communication.
  • It allows switching ON/OFF, Dim and save or recall up to 8 lighting scenes.
  • Installation in DIN rail.
  • Power supply: BUS KNX 24VDC.
  • Download Instructions.
  • Download User Guide.
CO KNT 002
  • KNX USB Interface Stick.
  • Establishes a bidirectional connection between a PC and the KNX installation bus.
  • Galvanic separation from the KNX bus.
  • Both ETS versions ETS3 or later and some visualization tools supports this interface..
  • Download Instructions

POWER SUPPLY

FA KNT 001 - Dinuy
FA KNT 001
  • EIB/KNX power supply produces and monitors EIB/KNX system voltage.
  • The bus line is decoupled from the power supply with the integrated choke.
  • A 30VDC auxiliary voltage is made available via an additional connection terminal.
  • This voltage can be used to supply a further bus line (in connection with a separate choke).The power supply is connected to the bus line with a bus connection terminal.
  • A reset is triggered by pressing the reset push button and lasts 22 seconds (regardless of the duration of the push button action).
  • The bus line disconnected from the power supply and the devices connected to this bus line are returned to their initial state.
  • Modular installation device. DIN-rail mounting.
  • Programing by ETS: program ETS3.
  • Download Instructions.

Este sitio web utiliza cookies para que usted tenga la mejor experiencia de usuario. Si continúa navegando está dando su consentimiento para la aceptación de las mencionadas cookies y la aceptación de nuestra política de cookies, pinche el enlace para mayor información.plugin cookies

ACEPTAR
Aviso de cookies