Constant Light Control

Flush Ceiling Mounting

  • 1-10V DAYLIGHT HARVESTING SENSOR – RE DMS 001

    • Daylight Harvesting system for 1-10V LED and Fluorescent lighting fixtures: uses daylight to offset the amount of artificial lighting needed to properly light a space, in order to reduce energy consumption. It is able to dim or switch lighting in response to changing daylight availability. It is designed to maintain a minimum recommended light level which will vary according to the needs and use of the stay.
    • Incorporates the Motion Detection function (optional), which makes the switch-on of the lighting conditional to the presence of people.
    • Minimum dimming level adjustment, avoiding switching the luminaires completely off.
    • Built-in output relay which allows disconnecting and switching the lighting fixtures off.
    • Possibility of expanding the motion detection area using Slave Sensors “DM SEN T03”.
    • Thanks to the accessory “AC DMS 001”, the manual switching and dimming control can be carried out via conventional Pushbutton / Switch,
    • Flush-ceiling mounting.
    • Application examples: offices, schools, hospitals…

  • DALI DAYLIGHT HARVESTING SENSOR – RE DMS DA1

    • Daylight Harvesting system for DALI LED and Fluorescent lighting fixtures: uses daylight to offset the amount of artificial lighting needed to properly light a space, in order to reduce energy consumption. It is able to dim or switch lighting in response to changing daylight availability. It is designed to maintain a minimum recommended light level which will vary according to the needs and use of the stay.
    • Broadcast DALI communication.
    • Incorporates the Motion Detection function (optional), which makes the switch-on of the lighting conditional to the presence of people.
    • Minimum dimming level adjustment, avoiding switching the luminaires completely off.
    • Possibility of expanding the motion detection area using Slave Sensors “DM SEN T03”.
    • Thanks to the accessory “AC DMS 001”, the manual switching and dimming control can be carried out via conventional Pushbutton / Switch.
    • Flush-ceiling mounting.
    • Application examples: offices, schools, hospitals…

  • 2-CHANNEL 1-10V DAYLIGHT HARVESTING SENSOR – RE DMS 003

    • Daylight Harvesting system for 1-10V LED and Fluorescent lighting fixtures: uses daylight to offset the amount of artificial lighting needed to properly light a space, in order to reduce energy consumption. It is able to dim or switch lighting in response to changing daylight availability. It is designed to maintain a minimum recommended light level which will vary according to the needs and use of the stay.
    • It has 2 channels which allows controlling two different lines of luminaires with an offset in the second line (luminaires farthest from the window).
    • Incorporates the Motion Detection function (optional), which makes the switch-on of the lighting conditional to the presence of people.
    • Minimum dimming level adjustment, avoiding switching the luminaires completely off.
    • Built-in output relay which allows disconnecting and switching the lighting fixtures off.
    • Possibility of expanding the motion detection area using Slave Sensors “DM SEN T03”.
    • Thanks to the accessory “AC DMS 001”, the manual switching and dimming control can be carried out via conventional Pushbutton / Switch.
    • Flush-ceiling mounting.
    • Application examples: offices, schools, hospitals…

  • 2-CHANNEL DALI DAYLIGHT HARVESTING SENSOR – RE DMS DA3

    • Daylight Harvesting system for DALI LED and Fluorescent lighting fixtures: uses daylight to offset the amount of artificial lighting needed to properly light a space, in order to reduce energy consumption. It is able to dim or switch lighting in response to changing daylight availability. It is designed to maintain a minimum recommended light level which will vary according to the needs and use of the space; for example, the commonly recommended light level for offices is 500 Lux on the desktop.
    • It has a 2 channels which allows controlling two different lines of luminaires with an offset in the second line (luminaires farthest from the window).
    • Incorporates the Motion Detection (PIR) function, which makes the switch-on of the lighting conditional to the presence of people (optional).
    • Two working modes are available: Daylight Harvesting + Motion detection or only Daylight Harvesting without motion detection.
    • Pre-configured from factory to achieve approximately 500 Lux in the workplace.
    • Possibility to set a minimum dimming level, avoiding switching the luminaires completely off.
    • Built-in output relay which allows disconnecting and switching the lighting fixtures off.
    • Flush-ceiling mounting.
    • Possibility of expanding the motion detection area using slave sensors (DM SEN T03).
    • Thanks to the accessory AC DMS 001, the manual switching and dimming control can be carried out via conventional Pushbutton / Switch,
    • Application examples: offices, schools, hospitals…

Surface Ceiling Mounting

  • 1-10V CONSTANT LIGHT CONTROL – RE DMS 004

    • Daylight Harvesting system for 1-10V LED and Fluorescent lighting fixtures: uses daylight to offset the amount of artificial lighting needed to properly light a space, in order to reduce energy consumption. It is able to dim or switch lighting in response to changing daylight availability. It is designed to maintain a minimum recommended light level which will vary according to the needs and use of the space; for example, the commonly recommended light level for offices is 500 Lux on the desktop.
    • It incorporates the Motion Detection (PIR) function, which makes the switch-on of the lighting conditional to the presence of people (optional).
    • Two working modes are available: Daylight Harvesting + Motion detection or only Daylight Harvesting without motion detection.
    • Pre-configured from factory to achieve approximately 500 Lux in the workplace.
    • Possibility to set a minimum dimming level, avoiding switching the luminaires completely off.
    • Built-in output relay which allows disconnecting and switching the lighting fixtures off.
    • Surface ceiling mounting.
    • Application examples: offices, schools, hospitals…

  • DALI CONSTANT LIGHT CONTROL DALI – RE DMS DA4

    • Daylight Harvesting system for DALI LED and Fluorescent lighting fixtures: uses daylight to offset the amount of artificial lighting needed to properly light a space, in order to reduce energy consumption. It is able to dim or switch lighting in response to changing daylight availability. It is designed to maintain a minimum recommended light level which will vary according to the needs and use of the space; for example, the commonly recommended light level for offices is 500 Lux on the desktop.
    • It incorporates the Motion Detection (PIR) function, which makes the switch-on of the lighting conditional to the presence of people (optional).
    • Two working modes are available: Daylight Harvesting + Motion detection or only Daylight Harvesting without motion detection.
    • Pre-configured from factory to achieve approximately 500 Lux in the workplace.
    • Possibility to set a minimum dimming level, avoiding switching the luminaires completely off.
    • Built-in output relay which allows disconnecting and switching the lighting fixtures off.
    • Surface ceiling mounting.
    • Application examples: offices, schools, hospitals…

Accessories

  • ACCESSORY FOR MANUAL CONTROL – AC DMS 001

    • Accessory which allows the manual control of the Harvesting Daylight Sensors through a Switch (Auto or Manual) and Pushbutton (On, Off and Dimming).
    • Compatible with: RE DMS 001, RE DMS DA1, RE DMS 03 or RE DMS DA3.

  • REMOTE CONTROL FOR DAYLIGHT HARVESTING SYSTEMS – CO REG R05

    • IR Remote Control for adjustment and control the Daylight Harvesting systems: RE DMS 001, RE DMS 003, RE DMS 004, RE DMS DA1, RE DMS DA3 and RE DMS DA4.
    • Its main function is the commission these systems remotely.
    • It also allows a manual control (on / off and dimming) of the lighting fixtures connected to the sensors.
    • IR communication, therefore, with a single remote control it is possible to set-up all the sensors in the same installation.

  • FLUSH-CEILING MOUNTED SLAVE MOTION DETECTOR – DM SEN T03

    Motion detector with PIR technology, flush ceiling installation.
    Slave detector for master movement detectors: DM TEC 004, DM TE1 002 or DM TE1 DA2.
    Up to 14 slaves can be installed for only one master movement detector, allowing to extend the coverage area.
    Time delay and brightness adjustable by potentiometers and remote control (EM MAN DM0). Sensitibity remote control.
    Possibility to memorized the bightness level by remote control.
    Coverage of 360º and Ø7m, at 2,5m of high.
    Rapid connection by RJ11 conector to the DM TEC 004.
    5,5 meters cable extender included.
    Aplication examples: Ofices corridors, hotels, schools…

  • ACCESSORY FOR MANUAL CONTROL – AC DMS 001

    • Accessory which allows the manual control of the Harvesting Daylight Sensors through a Switch (Auto or Manual) and Pushbutton (On, Off and Dimming).
    • Compatible with: RE DMS 001, RE DMS DA1, RE DMS 03 or RE DMS DA3.