News that you can find in our Booth

RE KNT 008: 8 channel Dimming Actuator
DINUY introduces its new and powerful 8-channel universal dimming actuator. Suitable for RLC+LED loads: LED lamps, incandescent and halogen lamps. Capable of loads of up to 250W on each of the eight channels. Incorporates two dimming technologies: leading and trailing edge. Both technologies can be selected via the parameterisation with the ETS. Each channel can be controlled manually via the push buttons on the front. This allows the lamps to be checked without needing the ETS bus. Modular housing for DIN-rail mounting (8-fold). Different LEDs indicate the status of each channel as well as error messages. Built-in protection against overload, short-circuit and overtemperature. The configuration of the device is performed via ETS5.

TM KNT 001: Touch Room Temperature Controller
KNX Room Temperature Glass Controller which measures the room temperature and humidity and displays the current value.
lncludes 6 capacitive buttons:
· 2 buttons (+/-) for adjustment of the room temperature.
· 1 button for switching on/off the system.
· 1 button for adjustment of the fan speed.
· 2 buttons for free configuration and functionality.
The Display shows the actual temperature or humidity value or the target value setpoint shift.
lncorporates 2 Analog/Digital lnputs.
Built-in Thermostat function for a heating or/and a cooling system.
The room temperature can optionally be sensed by the embedded temperature sensor or by an externa! temperature sensor connected to the terminal input (mixed value). lntegrated Relative Humidity sensor for controlling actuators for ambient humidity control.
The 2 free capacitive buttons can be configured for switching on/off, dimming, controlling shutters/blinds, managing scenes, etc.
The room temperature controller and pushbutton function are each independent sections of the device with their own parameter blocks in the ETS.
Flush-mounting design device. Mounting is done in common standard flush-mounted device boxes.
Equipped with KNX bus coupling unit (BCU).
Configuration is made using the KNX software ETS5 or later version.

In Dinuy we want to make life simpler and more homely in our homes. That’s why we have created a functional, intuitive APP from which you can control lighting, blinds, shutter and other house hold appliances from your smartphone or tablet.

Interface that allows the integration of RLC+LED loads within a DALI or DALI-2 lighting control system. Phase control dimming technology (leading- or trailing-edge), being valid for different types of load RLC+LED:
- 230V~ Dimmable LED lamps
- 12V~ Dimmable LED lamps with electronic transformer
- Incandescence and 230V Halogens
- 12V Halogens with electronic transformer
Depending on the type of load, it is possible to select the required dimming technology: leading-edge or trailing-edge. Broadcast or Addressable DALI communication. It admits the connection of an Auxiliary Pushbutton for the control of the Dimmer without the DALI Bus. The purpose of this input is to be able to test the lamps before installing the DALI Bus. In incorporates the possibility to select the dimming curve: Logarithmic or Linear. Protected against overloads and short circuits. It incorporates heating protection of resettable operation. Mounting into junction box.

EM KNT 003: Interface with 8 Digital lnputs/Outputs
Interface with 8 channels, which can either be configured as Digital lnputs or LEO Outputs in the ETS software.
Digital lnputs can be connected to conventional push buttons or free-voltage contacts. LEO Outputs can drive low voltage LEDs.
For each channel parameterized as Digital Input the following functions are available: switching, dimming, multiple switch, sequential switch, shutter/blind control, scene control, sending values or pulse counter.
The connecting lines of 30cm can be extended up to 200m.
The supply of the LEO outputs is provided by the Interface. Therefore no additional power supply is required.
The LEO outputs are protected against short circuits, overload and wrong polarity.
The compact design enables the device to be inserted in a conventional universal mechanism box, e.g. behind a push button or switch.
The bus connection is carried out via the bus-connecting terminal supplied. Programming and commissioning by ETS5 or later.

IT KNT 008: 8-channel Multifunction Switching Actuator
8-channel Switching Actuator or 4-channel Blind/Shutter Actuator.
Maximum switching capacity per channel up to 16A with 8 free voltage outputs.
Manual operation on device by pushbuttons for each channel even without bus connection. lncorporates 12 Analog/Binary lnputs.
LEO indicators of channel status LEO indicators of and failing status. Programming and commissioning by ETS5.
lt is possible to program different functions like timing, scenes, logical operations, torced function, etc.
DIN rail installation and 4 modules wide.
IT KNT 016: 16-channel Multifunction Switching Actuator
16-channel Switching Actuator or 8-channel Blind/Shutter Actuator.
Maximum switching capacity per channel up to 16A with 16 free voltage outputs.
Manual operation on device by push buttons for each channel even without bus connection.
lncorporates 24 Analog/Binary lnputs.
LEO indicators of channel status LEO indicators of and failing status. Programming and commissioning by ETS5.
lt is possible to program different functions like timing, scenes, logical operations, forced function, etc.
DIN rail installation and 8 modules wide.